==Getting Started==
==Getting Started==
{{UgSensorIntro|1124|Precision Temperature Sensor|Voltage Ratio Input port}}


===Checking the Contents===
{{UGbox|
'''You should have received:'''
* A precision temperature sensor
* A sensor cable
|
'''In order to test your new Phidget you will also need:'''
* A PhidgetInterfaceKit 8/8/8 or PhidgetTextLCD
* A USB cable
||}}


===Connecting the Pieces===
Next, you will need to connect the pieces:
{{UGbox|
[[Image:1124_0_Connecting_The_Hardware.jpg|400px|right|link=]]
#Connect the Precision Temperature Sensor to the Analog Input 6 on the PhidgetInterfaceKit 8/8/8 using the sensor cable.
# Connect the 1124 to the HUB0000 with the Phidget cable.
#Connect the PhidgetInterfaceKit to your PC using the USB cable.
# Connect the HUB0000 to your computer with the USB cable.
|
[[File:1124_0_Connecting_The_Hardware.jpg|400px|link=]]
||}}


===Testing Using Windows 2000 / XP / Vista / 7===
<br clear="all">
{{UGIntroDone|1124}}


{{UGwin}}
==Using the 1124==
{{UGcontrolpanelSensor|1124|HUB0000}}


===Running Phidgets Sample Program===
{{UGSensorVoltageRatioInput|1124|temperature (°C)}}


{{UGwin2|'''InterfaceKit-full'''}}
==Technical Details==
 
{{UGbox6|
Double Click on the [[File:Ph.jpg|link=]] icon to activate the Phidget Control Panel and make sure that the '''Phidget InterfaceKit 8/8/8''' is properly attached  to your PC. 
|[[File:1018_2_Control_Panel_Screen.jpg|400px|link=]]
|
#Double Click on '''Phidget InterfaceKit 8/8/8''' in the Phidget Control Panel to bring up InterfaceKit-full and check that the box labelled Attached contains the word True.
#Make sure that the Ratiometric box is Ticked.
#The ambient temperature of the sensor is displayed in the Analog Input box. The above value of 421 translates into 32.4 °C or 90.4°F.
#You can adjust the input sensitivity by moving the slider pointer.
#Click on the Sensors button to bring up the Advanced Sensor Form.
|
[[File:1124 0 InterfaceKit Screen.jpg|400px|link=]]
|
#In the Sensor 6 box, select the 1124 - Precision Temperature Sensor from the drop down menu.
#The ambient temperature measured by the sensor is shown here.
#Formula used to convert the analog input SensorValue into
|
[[File:1124 0 Advanced Sensor Form Screen.jpg|link=|400px]]
}}
 
===Testing Using Mac OS X===
 
{{UGmac| | }}
 
===Using Linux===
 
{{UGlinux}}


===Using Windows Mobile / CE 5.0 / CE 6.0===
===Higher Range Measurements===


{{UGce}}
If you don't use setSensorType() and simply convert from voltage to degrees using the formula below, you can measure temperatures up to 150°C. However, the components on the 1124 are rated for a maximum of 80°C, so this should only be done for short periods for testing purposes.  
 
==Technical Details==
===Temperature Range===
The temperature sensor component is rated at -50°C to +150°C, but the other components on the board, the connector and the cable are rated at -30°C to +80°C. In a fast prototyping environment the temperature ensor
board can be pushed to the ratings of the sensor component, but you should use the lower temperature ratings if you plan to use the 1124 in a commercial application.


===Formulas===
===Formulas===
The Formula to translate SensorValue into Temperature is:
{{UGSensorFormula|temperature (°C)}} The Formula to translate voltage ratio from the sensor into temperature is:




::<math>
::<math>
\text{Temperature (}^\circ \text{C)} = \text{(SensorValue} \times \text{0.2222) - 61.111}
\text{Temperature (}^\circ \text{C)} = \text{(VoltageRatio} \times \text{222.2) - 61.111}
</math>
</math>
 
<br clear="all">
 
{{UGotherint}}


{{UGasens}}
{{UGasens}}


==Product History==
{{UGnext|}}
{{UGhist}}
{{UGrow|December 2007 |0 |N/A |Product Release }}

Latest revision as of 15:46, 4 August 2021


Getting Started

Welcome to the 1124 user guide! In order to get started, make sure you have the following hardware on hand:


Next, you will need to connect the pieces:

1124 0 Connecting The Hardware.jpg
  1. Connect the 1124 to the HUB0000 with the Phidget cable.
  2. Connect the HUB0000 to your computer with the USB cable.


Now that you have everything together, let's start using the 1124!

Using the 1124

Phidget Control Panel

In order to demonstrate the functionality of the 1124, we will connect it to the HUB0000, and then run an example using the Phidget Control Panel on a Windows machine.


The Phidget Control Panel is available for use on both macOS and Windows machines. If you would like to follow along, first take a look at the getting started guide for your operating system:


Linux users can follow the getting started with Linux guide and continue reading here for more information about the 1124.

First Look

After plugging in the 1124 into the HUB0000, and the HUB0000 into your computer, open the Phidget Control Panel. You will see something like this:

HUB0000 Panel.jpg


The Phidget Control Panel will list all connected Phidgets and associated objects, as well as the following information:

  • Serial number: allows you to differentiate between similar Phidgets.
  • Channel: allows you to differentiate between similar objects on a Phidget.
  • Version number: corresponds to the firmware version your Phidget is running. If your Phidget is listed in red, your firmware is out of date. Update the firmware by double-clicking the entry.


The Phidget Control Panel can also be used to test your device. Double-clicking on an object will open an example.

Voltage Ratio Input

Double-click on a Voltage Ratio Input object in order to run the example:

1018 Sensors VoltageRatioInput.png


General information about the selected object will be displayed at the top of the window. You can also experiment with the following functionality:

  • Modify the change trigger and/or data interval value by dragging the sliders. For more information on these settings, see the data interval/change trigger page.
  • Select the 1124 from the Sensor Type drop-down menu. The example will now convert the voltage into temperature (°C) automatically. Converting the voltage to temperature (°C) is not specific to this example, it is handled by the Phidget libraries, with functions you have access to when you begin developing!


Technical Details

Higher Range Measurements

If you don't use setSensorType() and simply convert from voltage to degrees using the formula below, you can measure temperatures up to 150°C. However, the components on the 1124 are rated for a maximum of 80°C, so this should only be done for short periods for testing purposes.

Formulas

The Phidget libraries can automatically convert sensor voltage into temperature (°C) by selecting the appropriate SensorType. See the Phidget22 API for more details. The Formula to translate voltage ratio from the sensor into temperature is:



Phidget Cable

Analoginput.jpg

The Phidget Cable is a 3-pin, 0.100 inch pitch locking connector. Pictured here is a plug with the connections labelled. The connectors are commonly available - refer to the Analog Input Primer for manufacturer part numbers.

What to do Next

  • Programming Languages - Find your preferred programming language here and learn how to write your own code with Phidgets!
  • Phidget Programming Basics - Once you have set up Phidgets to work with your programming environment, we recommend you read our page on to learn the fundamentals of programming with Phidgets.