STC1005 Quick Start Guide: Difference between revisions
No edit summary |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 17: | Line 17: | ||
| '''Power Supply''' || An external power supply is required for this device (10-30VDC). | | '''Power Supply''' || An external power supply is required for this device (10-30VDC). | ||
|- | |- | ||
| '''Stepper Motor''' || Connect a | | '''Stepper Motor''' || Connect a bipolar stepper motor to these inputs. | ||
|- | |- | ||
| || | | || | ||
Line 30: | Line 30: | ||
{{UGC-Start}} | {{UGC-Start}} | ||
{{UGC-Entry|Bipolar Stepper Controller | {{UGC-Entry|Bipolar Stepper Controller|| | ||
| | |||
[[Image:STC1005-Stepper2.jpg|thumb|500px|link=https://cdn.phidgets.com/docs/images/d/d9/STC1005-Stepper2.jpg|<center>''Stepper Controller application - Phidget Control Panel (Windows)''</center>]] | [[Image:STC1005-Stepper2.jpg|thumb|500px|link=https://cdn.phidgets.com/docs/images/d/d9/STC1005-Stepper2.jpg|<center>''Stepper Controller application - Phidget Control Panel (Windows)''</center>]] | ||
* This channel allows you to control motor position, speed, current, and more. | * This channel allows you to control motor position, speed, current, and more. | ||
* View the [[Stepper API Guide]] for detailed information. | * View the [[Stepper API Guide]] for detailed information. | ||
}} | }} | ||
{{UGC-Entry|Voltage Input | {{UGC-Entry|Voltage Input|| | ||
| | |||
[[Image:STC1005-VoltageInput2.jpg|thumb|500px|link=https://cdn.phidgets.com/docs/images/d/df/STC1005-VoltageInput2.jpg|<center>''Supply Voltage Sensor application - Phidget Control Panel (Windows)''</center>]] | [[Image:STC1005-VoltageInput2.jpg|thumb|500px|link=https://cdn.phidgets.com/docs/images/d/df/STC1005-VoltageInput2.jpg|<center>''Supply Voltage Sensor application - Phidget Control Panel (Windows)''</center>]] | ||
* This controller includes built-in voltage sensing | * This controller includes built-in supply voltage sensing. | ||
* You can access this channel directly to implement custom monitoring or diagnostics. | * You can access this channel directly to implement custom monitoring or diagnostics. | ||
* For more information, view the 4A Stepper Phidget (STC1005) API. | * For more information, view the 4A Stepper Phidget (STC1005) API. | ||
Line 51: | Line 49: | ||
{{UGC-Start}} | {{UGC-Start}} | ||
{{UGC-Firmware}} | {{UGC-Firmware}} | ||
{{UGC-End}} | {{UGC-End}} |
Latest revision as of 16:57, 14 March 2025
Part 1: Setup
Part 2: Using Your Phidget
Connections Overview

VINT Port | This device must be connected to a VINT Hub Phidget to function. |
Power Supply | An external power supply is required for this device (10-30VDC). |
Stepper Motor | Connect a bipolar stepper motor to these inputs. |
Phidget Control Panel
Use the Phidget Control Panel to explore your device's functionality. Each channel is described below.

- This channel allows you to control motor position, speed, current, and more.
- View the Stepper API Guide for detailed information.
Part 3: Create your Program
Part 4: Other Considerations
Firmware Upgrade
MacOS users can upgrade device firmware by double-clicking the device row in the Phidget Control Panel.
Linux users can upgrade via the phidget22admin tool (see included readme for instructions).
Windows users can upgrade the firmware for this device using the Phidget Control Panel as shown below.
Firmware Downgrade
Firmware upgrades include important bug fixes and performance improvements, but there are some situations where you may want to revert to an old version of the firmware (for instance, when an application you're using is compiled using an older version of phidget22 that doesn't recognize the new firmware).
MacOS and Linux users can downgrade using the phidget22admin tool in the terminal (see included readme for instructions).
Windows users can downgrade directly from the Phidget Control Panel if they have driver version 1.9.20220112 or newer:
Firmware Version Numbering Schema
Phidgets device firmware is represented by a 3-digit number. For firmware patch notes, see the device history section on the Specifications tab on your device's product page.
- If the digit in the 'ones' spot changes, it means there have been bug fixes or optimizations. Sometimes these changes can drastically improve the performance of the device, so you should still upgrade whenever possible. These upgrades are backwards compatible, meaning you can still use this Phidget on a computer that has Phidget22 drivers from before this firmware upgrade was released.
- If the digit in the 'tens' spot changes, it means some features were added (e.g. new API commands or events). These upgrades are also backwards compatible, in the sense that computers running old Phidget22 drivers will still be able to use the device, but they will not be able to use any of the new features this version added.
- If the digit in the 'hundreds' spot changes, it means a major change has occurred (e.g. a complete rewrite of the firmware or moving to a new architecture). These changes are not backwards compatible, so if you try to use the upgraded board on a computer with old Phidget22 drivers, it will show up as unsupported in the Control Panel and any applications build using the old libraries won't recognize it either. Sometimes, when a Phidget has a new hardware revision (e.g. 1018_2 -> 1018_3), the firmware version's hundreds digit will change because entirely new firmware was needed (usually because a change in the processor). In this case, older hardware revisions won't be able to be upgraded to the higher version number and instead continue to get bug fixes within the same major revision.