1108 User Guide: Difference between revisions

From Phidgets Support
No edit summary
Line 72: Line 72:


{{UGasens}}
{{UGasens}}
==API==
{{SensorAPI}}


==Product History==
==Product History==
{{UGhist}}
{{UGhist}}
{{UGrow|June 2005|0|N/A|Product Release}}
{{UGrow|June 2005|0|N/A|Product Release}}

Revision as of 15:16, 21 August 2012

1108.jpg
Go to this device's product page


Getting Started

Checking the Contents

You should have received:

  • A Magnetic Sensor
  • A Sensor Cable
  • 2 small magnets

In order to test your new Phidget you will also need:

  • A PhidgetInterfaceKit 8/8/8
  • A USB Cable

Connecting the Pieces

  1. Connect the Magnetic Sensor to the Analog Input 6 on the PhidgetInterfaceKit 8/8/8 board using the sensor cable.
  2. Connect the PhidgetInterfaceKit to your PC using the USB cable.

1108 0 Connecting The Hardware.jpg

Testing Using Windows 2000 / XP / Vista / 7

Make sure you have the current version of the Phidget library installed on your PC. If you don't, follow these steps:

  1. Go to the Quick Downloads section on the Windows page
  2. Download and run the Phidget21 Installer (32-bit, or 64-bit, depending on your system)
  3. You should see the Ph.jpg icon on the right hand corner of the Task Bar.

Running Phidgets Sample Program

Double clicking on the Ph.jpg icon loads the Phidget Control Panel; we will use this program to ensure that your new Phidget works properly.

The source code for the InterfaceKit-full sample program can be found in the quick downloads section on the C# Language Page. If you'd like to see examples in other languages, you can visit our Languages page.

Updating Device Firmware

If an entry in this list is red, it means the firmware for that device is out of date. Double click on the entry to be given the option of updating the firmware. If you choose not to update the firmware, you can still run the example for that device after refusing.

Double Click on the Ph.jpg icon to activate the Phidget Control Panel and make sure that the Phidget InterfaceKit 8/8/8 is properly attached to your PC.

1018 2 Control Panel Screen.jpg
  1. Double Click on Phidget InterfaceKit 8/8/8 in the Phidget Control Panel to bring up InterfaceKit-full and check that the box labelled Attached contains the word True.
  2. Make sure that the Ratiometric box is Ticked.
  3. Move one of the magnets close to the sensor and watch the value in the Analog In box go from 500 to a 1000 or from 500 to 0 depending on the magnet polarity facing the sensor.
  4. You can adjust the input sensitivity by moving the slider pointer.
  5. Click on the Sensors button to bring up the Advanced Sensor Form.
Sensor InterfaceKit Screen 421.jpg
  1. In the Sensor 6 box, select the 1108 - Magnetic Sensor from the drop down menu.
  2. The magnetic field strength as reported by the sensor is shown here.
  3. Formula used to convert the analog input SensorValue into Gauss.
1108 0 Advanced Sensor Form Screen.jpg

Testing Using Mac OS X

  1. Go to the Quick Downloads section on the Mac OS X page
  2. Download and run the Phidget OS X Installer
  3. Click on System Preferences >> Phidgets (under Other) to activate the Preference Pane
  4. Make sure that the Phidget InterfaceKit 8/8/8 is properly attached.
  5. Double Click on Phidget InterfaceKit 8/8/8 in the Phidget Preference Pane to bring up the InterfaceKit-full Sample program. This program will function in a similar way as the Windows version.

Using Linux

For a step-by-step guide on getting Phidgets running on Linux, check the Linux page.

Using Windows Mobile / CE 5.0 / CE 6.0

Template:UGce

Technical Details

This linear Hall-effect sensor is optimized, sensitive, and temperature-stable. It is a ratiometric Hall-effect sensor which provides a voltage output that is proportional to the applied magnetic field. Accuracy can be improved on aspecific device with offset and/or gain calibration (using known flux).

Formulas

The Formula to translate SensorValue into Gauss is:

Φ(G) = 500 - SensorValue

Template:UGotherint

Phidget Cable

Analoginput.jpg

The Phidget Cable is a 3-pin, 0.100 inch pitch locking connector. Pictured here is a plug with the connections labelled. The connectors are commonly available - refer to the Analog Input Primer for manufacturer part numbers.

API

Template:SensorAPI

Product History

Template:UGhist Template:UGrow