1125 User Guide

From Phidgets Legacy Support


Getting Started

Checking the Contents

You should have received:

  • A humidity/temperature sensor
  • Two sensor cables

In order to test your new Phidget you will also need:

  • A PhidgetInterfaceKit 8/8/8 or a PhidgetTextLCD
  • A USB cable

Connecting the Pieces

  1. Connect the Sensor’s Temperature Output to an Analog Input on the PhidgetInterfaceKit 8/8/8 using one of the sensor cable.
  2. Connect the Sensor’s Humidity Output to an Analog Input on the PhidgetInterfaceKit 8/8/8 using the second sensor cable.
  3. Connect the InterfaceKit 8/8/8 to your PC using a USB cable.

1125 0 Connecting The Hardware.jpg

Testing Using Windows 2000 / XP / Vista / 7

Make sure you have the current version of the Phidget library installed on your PC. If you don't, follow these steps:

  1. Go to the Quick Downloads section on the Windows page
  2. Download and run the Phidget21 Installer (32-bit, or 64-bit, depending on your system)
  3. You should see the Ph.jpg icon on the right hand corner of the Task Bar.

Running Phidgets Sample Program

Double clicking on the Ph.jpg icon loads the Phidget Control Panel; we will use this program to ensure that your new Phidget works properly.

The source code for the InterfaceKit-full sample program can be found in the quick downloads section on the C# Language Page. If you'd like to see examples in other languages, you can visit our Languages page.

Updating Device Firmware

If an entry in this list is red, it means the firmware for that device is out of date. Double click on the entry to be given the option of updating the firmware. If you choose not to update the firmware, you can still run the example for that device after refusing.

Double Click on the Ph.jpg icon to activate the Phidget Control Panel and make sure that the Phidget InterfaceKit 8/8/8 is properly attached to your PC.

1018 2 Control Panel Screen.jpg
  1. Double Click on Phidget InterfaceKit 8/8/8 in the Phidget Control Panel to bring up InterfaceKit-full and check that the box labelled Attached contains the word True.
  2. Make sure that the Ratiometric box is Ticked.
  3. Check the values in the Analog In boxes. The humidity value of 318, for example, is equal to 22% relative humidity and the temperature value of 389 is equal to 23 degrees Celsius.
  4. You can adjust the input sensitivity by moving the slider pointer.
  5. Click on the Sensors button to bring up the Advanced Sensor Form.

1125 0 InterfaceKit Screen.jpg

  1. In the Advanced Sensor Form, select the 1125 - Humidity/Temperature Sensor [H] from the drop down menu to get a display for the humidity sensor functionality.
  2. The measured relative humidity.
  3. Formula used to convert the analog input SensorValue into relative humidity.
  4. Select the 1125 - Humidity/Temperature Sensor [T] from the drop down menu to get a display for the temperature sensor functionality.
  5. The measured ambient temperature.
  6. Formula used to convert the analog input SensorValue into temperature.

1125 0 Advanced Sensor Form Screen.jpg

Testing Using Mac OS X

  1. Go to the Quick Downloads section on the Mac OS X page
  2. Download and run the Phidget OS X Installer
  3. Click on System Preferences >> Phidgets (under Other) to activate the Preference Pane
  4. Make sure that the is properly attached.
  5. Double Click on in the Phidget Preference Pane to bring up the Sample program. This program will function in a similar way as the Windows version.

Using Linux

For a step-by-step guide on getting Phidgets running on Linux, check the Linux page.

Using Windows Mobile / CE 5.0 / CE 6.0

For a step-by-step guide on getting Phidgets running on Windows CE, check the Windows CE page.

Technical Details

Relative Humidity

The sensor measures the relative humidity of the environment around the sensor. Built in temperature compensation produces a linear output ranging from 10% to 95% relative humidity. Values outside of this range may be usable but will have increased error.

Formulas

The Formula to translate SensorValue into Relative Humidity is:

Temperature

This device is a precision temperature to voltage converter that outputs a voltage that is directly proportional to temperature. The temperature sensor component is rated at -40°C to +100°C, but the other components on the board, the connector and the cable are rated at -30°C to +80°C. In a fast prototyping environment the temperature sensor board can be pushed to the ratings of the sensor component, but you should use the lower temperature ratings if you plan to use the 1124 in a commercial application.

Formulas

The Formula to translate SensorValue into Temperature is:

Failed to parse (SVG (MathML can be enabled via browser plugin): Invalid response ("Math extension cannot connect to Restbase.") from server "https://wikimedia.org/api/rest_v1/":): {\displaystyle \text{Temperature (°C)} = (\text{SensorValue} \times 0.22222) \minus 61.11}

Other Interfacing Alternatives

If you want maximum accuracy, you can use the RawSensorValue property from the PhidgetInterfaceKit. To adjust a formula, substitute (SensorValue) with (RawSensorValue / 4.095) If the sensor is being interfaced to your own Analog to Digital Converter and not a Phidget device, our formulas can be modified by replacing (SensorValue) with (Vin * 200). It is important to consider the voltage reference and input voltage range of your ADC for full accuracy and range.


Each Analog Input uses a 3-pin, 0.100 inch pitch locking connector. Pictured here is a plug with the connections labelled. The connectors are commonly available - refer to the Analog Input Primer for manufacturer part numbers.

Analoginput.jpg

Product History

Date Board Revision Device Version Comment
May 2008 0 N/A Product Release