Notice: This page contains information for the legacy Phidget21 Library. Phidget21 is out of support. Bugfixes may be considered on a case by case basis. Phidget21 does not support VINT Phidgets, or new USB Phidgets released after 2020. We maintain a selection of legacy devices for sale that are supported in Phidget21. We recommend that new projects be developed against the Phidget22 Library.
|
Mechanical Relay Primer
Introduction
Mechanical relays are designed to turn on or turn off the power supplied to other devices using a simple signal from a digital output. They are similar to Solid State Relays except they are less expensive, but are also less sophisticated and have a shorter lifespan. You can use them to control LEDs, heaters, appliances, and generally powered device as long as the power you're switching falls within the limits of the relay you're using.
Phidgets sells boards with multiple relays on them, making it easy to control many separate circuits when used with an Interface Kit (or any device with enough Digital Outputs).
How it works
Mechanical relays use a simple electromagnetic coil to open or close the circuit. When current runs through the input and energizes the coil, it creates a small magnetic field which either pulls the arm of the switch away from the other contact of the switch, or pushes it down to close the switch depending on the how the switch is made. A relay also serves as an isolator, because the control (input) and load (output) ends of the relay are not directly connected. This allows you to protect the device you're using to control the relay from power surges in your application.
- (add diagram)
Basic Use
Controlling a mechanical relay is as easy as turning on an LED. Any Phidgets device with a Digital Output will be able to control a mechanical relay.
Choosing a Relay
Since mechanical relays are nothing more than a controllable switch, they support both AC and DC operation.
The major deciding factor in choosing a mechanical relay is the amount of current it's capable of switching. For example, the most current you can switch with the largest mechanical relay we sell is 5A DC or 10A AC. If the load you're switching consumes more current than a mechanical relay can handle, take a look at our Solid State Relays.
Types or Classes
Switch Type
One of the major characteristics of a mechanical relay is the design of the switch inside.
Single Pole, Single Throw (SPST)
This is a simple switch with only one path for the current to follow. The relay is either designed to be normally open or normally closed. If it is normally open, the arm of the switch is held away from the contact with a spring when the relay is off and the electromagnet pulls the arm to make contact and close the switch when the relay is turned on. If it is normally closed, the arm of the switch is held to the contact when the relay is off, and the electromagnet pulls the arm away when the relay is turned on.
Single Pole, Double Throw (SPDT)
This switch has two paths for the current to follow. This type of relay is useful if you want to toggle power between two different loads, as pictured. You can also use a SPDT relay as a single pole, single throw switch, and it can function as normally open or normally closed depending on which pins you connect the load to. (another diagram)
Double Pole, Double Throw (DPDT)
This switch functions the same as a SPDT switch, except there are two of them, but are both controlled by a single input on the relay. You can use this type of switch to simultaneously control two separate circuits.
Switching
Relays are designed to be controlled by a particular voltage applied to the coil. If you buy a relay product from Phidgets with integrated electronics, this is taken care of for you. If you are integrating your own relay, you'll want to keep an eye on the specifications.
The relay coil is also specified for a particular current. For example, a 5V relay might require 70mA. If you connect this relay to a very weak source of 5V, like a digital output, the output will not be able to provide 70mA, and there will not be enough voltage to switch the relay.
Conclusion
- Much the same as the Introduction, but using reference to supplied information to justify the statements.
Products in this Category
Glossary
Switch Type
- SPST - either normally open or normally closed. Simple on/off switch.
- SPDT - 3 pins, has both a NO and NC pin and can function like a SPST switch of either type, or can be used to toggle power between two different loads.
- DPDT - Same as SPDT but there are two controlled by the same relay input. Useful for controlling 2 seperate circuits in a synchronized manner.
- Potential selection criteria for specific switching circuits.
Contact Arcing
- As the switch moves from the "on" position to the "off" position (and vice-versa) there is a moment when the arm of the switch in close enough to the contact that electricity will arc through the air, creating lots of heat and possibly damaging the contact. (Diagram would be useful)
- Arcing can lead to sticking, where the switch welds itself closed. If your relay is always on, it might be stuck.
- Arcing will be more severe with higher power loads or highly inductive loads.
- Arcing is expected, but can be mitigated by:
- For DC, feedback diode across load
- For AC, Snubber circuit or
- MOV or
- TVS
Switching Speed
- Lifespan of relay is measured in number of contacts, not time in use. Faster switching -> shorter life.
- Switching is audible - you can hear the switching, which might be annoying / undesirable, or it might be good as a confirmation the system is operating.
- Switching speed is limited by heating in the contacts - the arcing generates heat, and switching high loads faster than the rated switching speed will cause the relay to overheat.
Operating Time
- Time it takes for the arm of the switch to connect with the contact after being activated
- If 10ms is too slow, look at SSRs
Control Voltage
- Can be controlled via digital output
- Relay offers isolation between load circuit and control circuit
Maximum (AC/DC) Switching Voltage
- Secondary selection criteria.
Maximum (AC/DC) Switching Current
- Main selection criteria.
- If they need to switch more than 5A DC, or 10A AC, go to SSRs
- Inductive loads- does the same multiplier apply as for SSRs?
Minimum Switching Current
- A certain amount of current is needed on the LOAD side of a relay.
- Oxide films build up on the contacts, so this minimum is required to conduct through them.
- This spec determines whether or not the relay can switch a signal instead of power.
- If you are switching a signal rather than power, contact bounce could be a problem.