Error 7013 with the example for the 1043 accelerometer

Supporting Labview 2012 and up
Post Reply
gouwzee
Fresh meat
Posts: 4
Joined: Sun Nov 20, 2016 5:27 pm
Contact:

Error 7013 with the example for the 1043 accelerometer

Post by gouwzee »

I just purchased a 1043 accelerometer and the 1040 GPS usb devices. I want to use the sensors with labview 2015 or 2016 on a win7 machine. The sensors show up fine in the phidgets control panel and can be viewed from there as well.
The problem arises when I use the example Labview code for the accelerometer. This one always yields error 7013 - Given timeout has been exceeded.
More specifically, the error is generated in the subVI _WaitAttach.vi, although the GPS example calls exactly the same vi without any problem.

No matter what I try; other OS, other labview versions, only with accelerometer connected, Labview run as administrator, system reboots etc etc. All at no avail.

I would really like some suggestions for a solution. I am glad there is a Labview library provided, but it seems aging quite a bit.
User avatar
mparadis
Site Admin
Posts: 660
Joined: Fri Oct 28, 2011 12:17 pm
Contact:

Re: Error 7013 with the example for the 1043 accelerometer

Post by mparadis »

"Accelerometer" is an old example file for an obsolete Phidget board. Try using the "Spatial" example with your 1043.
gouwzee
Fresh meat
Posts: 4
Joined: Sun Nov 20, 2016 5:27 pm
Contact:

Re: Error 7013 with the example for the 1043 accelerometer

Post by gouwzee »

Yes! That's it, thank you! :D