Error 7050: Phidget Frequency Counter Data Inteval not settable

Supporting Labview 2012 and up
Post Reply
alexeialexandrovski
Phidgetsian
Posts: 10
Joined: Sat Jun 29, 2019 1:45 am
Contact:

Error 7050: Phidget Frequency Counter Data Inteval not settable

Post by alexeialexandrovski »

Windows 10, LabVIEW 2020, current, updated Phidgets software.

Library function PhidgetEncoder_setDataInterval fails with recently purchased DAQ1400_0, firmware version 121.

Any attempt to change data interval input from -1 results in error 7050, Wrong Device, right at the output of the function.

It is only with LabVIEW. In the Phidgets Control Panel you can set Data Interval within 20 to 1800 ms range and it works.
jdecoux
Labview Developer
Posts: 180
Joined: Mon Nov 13, 2017 10:20 am
Contact:

Re: Error 7050: Phidget Frequency Counter Data Inteval not settable

Post by jdecoux »

A fix has been made to FrequencyCounterStart.vi to call the correct DataInterval function, pending release. Thanks for pointing it out!

In the meantime, you can use the FrequencyCounterSetDataInterval.vi from the FrequencyCounter palette.
jdecoux
Labview Developer
Posts: 180
Joined: Mon Nov 13, 2017 10:20 am
Contact:

Re: Error 7050: Phidget Frequency Counter Data Inteval not settable

Post by jdecoux »

A new version of the Phidget22 LabVIEW library has been released with this issue fixed.