Quantity Available: 5
Qty | Price |
---|---|
5 | $180.00 |
10 | $172.50 |
This AC Active Power sensor measures AC power up to 7500W. Powered by an external 12VDC power supply, the AC Active Power Sensor provides a 0 to 5VDC analog signal that is linearly proportional to the power measured.
The AC Power Sensor can easily be mounted using the screw holes, or on a 35mm wide DIN rail for quick installation. The terminal blocks accommodate conductors of up to AWG #16. The window in the Sensor has a diameter of 6.5mm.
The power sensor connects to an analog input on Phidgets I/O boards. The formula to translate the output voltage into Power is:
P(W) = (Vout – SensorOffset) * 250
To determine the offset in your system, record the output voltage when there is no power applied to the sensor. Use that value in the place of SensorOffset in the formula above.
You can use a 12V sensor adapter to connect this sensor to your InterfaceKit or Hub. See the Connection & Compatibility tab for more details.
Warning: The AC Power Sensor needs to be attached in parallel with the line voltage. This requires cutting and using loose ends of high power cables. ALWAYS be sure to turn off the power running through the cables while manipulating and before cutting the cables. When attaching the cables, be sure to follow your country’s wiring code to ensure safe installment of the sensors and to reduce the risk of injury and fire. If you are uncomfortable, consult with a certified electrician.
This power sensor requires a 12V power supply and outputs a 0-5V signal depending on the power measurement. For a simple way to provide 12 volts, you can use our 12V sensor adapter. It uses the 5V supply from your InterfaceKit or Hub and steps it up to 12V while simultaneously passing the 0-5V signal from the sensor into the Phidget cable.
To connect the sensor, connect the terminals as follows:
Function | 3517 - Power Sensor | 1144 - 12V Sensor Adapter |
---|---|---|
+12V | 5 | +12V |
Ground | 6 | GND |
Data | 8 | ANLG |
Product | Sensor Properties | |
---|---|---|
Part Number | Price | Controlled By |
12V Sensor Adapter
|
$11.00 | Voltage Input (0-5V) |
Alternatively, you can use the Versatile Input Phidget, which is a VINT-controlled device that can interface a wide variety of sensors, including transducers that run on a 12V supply.
To connect the sensor, connect the terminals as follows:
Function | 3517 - Power Sensor | 1144 - 12V Sensor Adapter |
---|---|---|
+12V | 5 | 12V/24V |
Ground | 6 | Gnd |
Data | 8 | Analog |
Product | Board Properties | |
---|---|---|
Part Number | Price | Controlled By |
Versatile Input Phidget
|
$20.00 | VINT |
You may need hook-up wire to connect this sensor's terminals to your 12V Sensor Adapter. Here's a list of wire that we sell for this purpose:
Product | Physical Properties | ||
---|---|---|---|
Part Number | Price | Cable Length | Cable Gauge |
Phidget Cable Extension Wire 22AWG
|
$0.75/Meter | — | 22 AWG |
Hook-up Wire 14AWG Black
|
$0.75/Meter | — | 14 AWG |
Hook-up Wire 14AWG Red
|
$0.75/Meter | — | 14 AWG |
Hook-up Wire 18AWG Black
|
$0.50/Meter | — | 18 AWG |
Hook-up Wire 18AWG Red
|
$0.50/Meter | — | 18 AWG |
Hook-up Wire 22AWG Black
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG Blue
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG Brown
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG Green
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG Red
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG White
|
$0.25/Meter | — | 22 AWG |
Hook-up Wire 22AWG Yellow
|
$0.25/Meter | — | 22 AWG |
2 wire 100' Twisted Cable
|
$4.00 | 30.5 m | 26 AWG |
Sensor Properties | |
---|---|
Controlled By | Voltage Input (0-5V) |
Sensor Type | Power (AC) |
Sensor Output Type | Non-Ratiometric |
Input Frequency | 60 Hz |
Input Current Min | 0 A |
Input Current Max | 5 A |
Input Voltage Min (AC) | 0 V AC |
Input Voltage Max (AC) | 250 V AC |
Input Power Min | 0 W |
Input Power Max | 1.3 kW |
Measurement Error Max | 0.5 % |
Sensor Response Time Max | 500 ms |
Electrical Properties | |
Supply Voltage Min | 12 V DC |
Supply Voltage Max | 12 V DC |
Current Consumption Max | 25 mA |
Output Voltage Min | 0 V DC |
Output Voltage Max | 5 V DC |
Isolation Voltage (AC) | 1.5 kV AC |
Isolation Voltage (DC) | 2.5 kV DC |
Physical Properties | |
Recommended Wire Size | 12 - 24 AWG |
Wire Window Size | 6.5 mm |
Operating Temperature Min | 0 °C |
Operating Temperature Max | 50 °C |
Customs Information | |
Canadian HS Export Code | 9030.33.00 |
American HTS Import Code | 9030.33.38.00 |
Country of Origin | CN (China) |
Product | Sensor Properties | |||
---|---|---|---|---|
Part Number | Price | Input Power Max | Input Voltage Max (AC) | Input Current Max |
AC Active Power Sensor 0-110V*0-15A (60Hz)
|
$187.50 | 1.7 kW | 110 V AC | 15 A |
AC Active Power Sensor 0-110V*0-5A (60Hz)
|
$187.50 | 550 W | 110 V AC | 5 A |
AC Active Power Sensor 0-250V*0-5A (60Hz)
|
$187.50 | 1.3 kW | 250 V AC | 5 A |